01262
From Ross-Tech Wiki
Revision as of 04:43, 28 November 2006 by RtWiKiSyS0p (talk | contribs)
01262 - Solenoid Valve for Boost Pressure Control (N75)
01262 - Solenoid Valve for Boost Pressure Control (N75): Short to Ground
Possible Symptoms
- Reduced Power Output
- Overrun Cut-Off until Boost pressure falls to a non-critical level
- Boost Pressure too High
Possible Causes
- Wiring from/to Solenoid Valve for Boost Pressure Control (N75) faulty (Short to Ground)
- Solenoid Valve for Boost Pressure Control (N75) faulty
Possible Solutions
- Check/Replace Solenoid Valve for Boost Pressure Control (N75)
Special Notes
- Often seen in combination with 00544 (Maximum Boost Pressure Exceeded).
01262 - Solenoid Valve for Boost Pressure Control (N75): Short to Plus
Possible Symptoms
- Reduced Power Output
- Boost Pressure too Low
Possible Causes
- Wiring from/to Solenoid Valve for Boost Pressure Control (N75) faulty (Short to Plus)
- Solenoid Valve for Boost Pressure Control (N75) faulty
Possible Solutions
- Check/Replace Solenoid Valve for Boost Pressure Control (N75)
01262 - Solenoid Valve for Boost Pressure Control (N75): Output Open
Possible Symptoms
- Reduced Power Output
- Boost Pressure too Low
Possible Causes
- Wiring from/to Solenoid Valve for Boost Pressure Control (N75) faulty (Open Circuit)
- Solenoid Valve for Boost Pressure Control (N75) faulty
Possible Solutions
- Check/Replace Solenoid Valve for Boost Pressure Control (N75)