01317
From Ross-Tech Wiki
Revision as of 08:13, 29 November 2007 by RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 01317 - Instrument Cluster (J285) == === 01317 - Instrument Cluster (J285): No Communications === ==== Possible Causes ==== * CAN-Databus Wiring/Connectors from/to Instr...)
01317 - Instrument Cluster (J285)
01317 - Instrument Cluster (J285): No Communications
Possible Causes
- CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285) faulty
- Fault(s) stored in Instrument Cluster (J285)
Possible Solutions
- Check CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285)
- Check Measuring Value Blocks (MVB)
- Usually Measuring Value Blocks (MVB) 125+ show the current Communication Status
01317 - Instrument Cluster (J285): Check DTC Memory
Possible Causes
- Fault(s) stored in Instrument Cluster (J285)
Possible Solutions
- Check Instrument Cluster (J285) for Fault Codes
Special Notes
- Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality