01809
From Ross-Tech Wiki
01809 - Actuating Motor for Temperature Flap; Left (V158)
01800 - Actuating Motor for Temperature Flap; Blocked or No Voltage
Possible Symptoms
- HVAC temperature inconsistent.
Possible Causes
- Left Temperature Flap (V158) faulty
- Wiring/Connectors between Left Temperature Flap (V158) and A/C Control Head (E87) faulty
- Temperature flap stuck or obstructed (unable to move freely)
Possible Solutions
- Check Wiring/Connectors between Left Temperature Flap (V158) and A/C Control Head (E87) faulty
- Run Output Tests to make sure Left Temperature Flap (V158) can operate freely.