00349
From Ross-Tech Wiki
00349 - Solenoid Valve 10 (N283)
00349 - Solenoid Valve 10 (N283): Open or Short to Ground
00349 - Solenoid Valve 10 (N283): Open or Short to Plus
Possible Symptoms
- Shifting issues
Possible Causes
- Damaged wiring harness
- Failed Solenoid Valve
- Failed TCM
Possible Solutions
- Ohm test wiring harness
Special Notes
- When found on the 6 speed 09G transmission:
- Solenoid Valve 10 (N283) is also noted as The Pressure Control Valve 6 (N271)