00575
From Ross-Tech Wiki
Revision as of 11:35, 8 October 2012 by Andy (talk | contribs) (→00575 - Intake Manifold Pressure: Control Difference)
00575 - Intake Manifold Pressure: Control Limit Not Reached
Possible Symptoms
- Sudden complete loss of Power
- Reduced Power
Possible Causes
- Hoses incorrect connected, disconnected, blocked or leaking
- Pressure Unit for Turbo Charger defective
- Solenoid Valve for Boost Pressure Control (N75) defective
Possible Solutions
- Check Hoses
- Check Pressure Unit for Turbo Charger
- Check Solenoid Valve for Boost Pressure Control (N75)
- Check Basic Setting > MVB 011
00575 - Intake Manifold Pressure: Control Limit Exceeded
Possible Symptoms
- Sudden complete loss of Power
- Reduced Power
- Charge Pressure too High
Possible Causes
- Solenoid Valve for Boost Pressure Control (N75) defective
- Turbo Charger defective
Possible Solutions
- Check Solenoid Valve for Boost Pressure Control (N75)
- Check Basic Setting > MVB 011
00575 - Intake Manifold Pressure: Control Difference
Possible Symptoms
- Reduced Power
Possible Causes
- Solenoid Valve for Boost Pressure Control (N75) defective
- Hoses incorrect connected, disconnected, blocked or leaking
- In 1Z/AHU engines, stuck/rusted wastegate or actuator.
Possible Solutions
- Check Solenoid Valve for Boost Pressure Control (N75)
- Check Hoses