Difference between revisions of "Readiness - APB Engine Code"

From Ross-Tech Wiki
Line 107: Line 107:
  
  
* <u>Ignition ON and Engine <b>ON between 1800 and 2200 rpm</b></u><br>
+
* <u>Ignition ON and Engine <b>ON between 1520 and 2280 rpm</b></u><br>
  
  
Line 113: Line 113:
 
''Pre-cat O2 sensors response time test''<br>
 
''Pre-cat O2 sensors response time test''<br>
  
Select group 041<br>
+
Select group 034<br>
 
'''[Go]'''<br>
 
'''[Go]'''<br>
 
'''[Switch to basic settings]'''<br>
 
'''[Switch to basic settings]'''<br>
Leave it in Basic Settings until there are kOhm readings in the first and third fields<br>
+
Leave it in Basic Settings until the fourth field reads B1-S1 OK<br>
 
'''[Switch to Meas. Blocks]'''<br>
 
'''[Switch to Meas. Blocks]'''<br>
Select group 042<br>
+
Select group 035<br>
 
'''[Go]'''<br>
 
'''[Go]'''<br>
 
'''[Switch to basic settings]'''<br>
 
'''[Switch to basic settings]'''<br>
Leave it in Basic Settings until there are kOhm readings in the first and third fields<br>
+
Leave it in Basic Settings until the fourth field reads B2-S1 OK<br>
 +
'''[Switch to Meas. Blocks]'''<br>
 +
 
 +
 
 +
 
 +
* <u>Ignition ON and Engine <b>ON at idle</b></u><br>
 +
 
 +
 
 +
 
 +
''O2 sensor control test''<br>
 +
 
 +
Select group 037<br>
 +
'''[Go]'''<br>
 +
'''[Switch to basic settings]'''<br>
 +
Leave it in Basic Settings until the fourth field reads Syst. OK<br>
 +
'''[Switch to Meas. Blocks]'''<br>
 +
Select group 038<br>
 +
'''[Go]'''<br>
 +
'''[Switch to basic settings]'''<br>
 +
Leave it in Basic Settings until the fourth field reads Syst. OK<br>
 
'''[Switch to Meas. Blocks]'''<br>
 
'''[Switch to Meas. Blocks]'''<br>

Revision as of 15:54, 5 October 2006

Manually Generating Readiness

  • Ignition ON and Engine OFF


Reading and clearing fault codes

[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]


Throttle Body Alignment

[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]


Transmission kickdown (applies to Auto Trans vehicles only!)

Select group 063
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]


[Done, Go Back]
[Close Controller, Go Back]


  • Ignition ON and Engine ON at idle


Fuel leakage test

[Select]
[01 - Engine]
[Measuring Blocks - 08]
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]


Evap purge test

Select group 070
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads EVAP OK
[Switch to Meas. Blocks]


A/F control test

Select group 107
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]


  • Ignition ON and Engine ON between 1800 and 2200 rpm


O2 sensor heater test

Select group 041
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]
Select group 042
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]


  • Ignition ON and Engine ON at idle


Post-cat O2 sensors readiness test

Select group 036
[Go]
[Switch to basic settings]
Leave it in Basic Settings until you see B1-S2 OK in the first field and B2-S2 OK in the third field
[Switch to Meas. Blocks]


  • Ignition ON and Engine ON between 1520 and 2280 rpm


Pre-cat O2 sensors response time test

Select group 034
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads B1-S1 OK
[Switch to Meas. Blocks]
Select group 035
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads B2-S1 OK
[Switch to Meas. Blocks]


  • Ignition ON and Engine ON at idle


O2 sensor control test

Select group 037
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst. OK
[Switch to Meas. Blocks]
Select group 038
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst. OK
[Switch to Meas. Blocks]