01406 - No Flame

Possible Symptoms

  • Smoke

Possible Causes

  • Air in Fuel Supply
    • Possibly due to "dynamic driving style" while tank on reserve.
    • Fuel Supply leaking

Possible Solutions

  • Check Fuel Supply for Leaks
  • Perform Function Test until all Air is out of the Fuel Supply System
    • Perform Basic Setting (see Special Notes for further Instructions)

Special Notes

  • This fault may occur due to the auxiliary heating start up, while all related components and functions are free of faults.