Difference between revisions of "Audi A4 (8E) Automatic Roof"
From Ross-Tech Wiki
Line 12: | Line 12: | ||
* If Adaptation will not set with only the 02000 fault present, check TSB 61-08-05 (2010940, NAR only) | * If Adaptation will not set with only the 02000 fault present, check TSB 61-08-05 (2010940, NAR only) | ||
− | + | * If fault code [[00003]] - Control Module: Defective -or- Control Module: No or Incorrect Basic Setting / Adaptation will not clear after replacing the 26 module try locking the vehicle doors so the CAN Bus modules go into sleep mode. Upon waking back up, the internal CAN Bus modules on the Comfort Bus may begin to communicate properly. | |
== Measuring Block Data == | == Measuring Block Data == |
Revision as of 14:41, 16 March 2012
Adaptation
Channel 01: Reset
Prerequisites:
- Automatic Roof closed
- Measuring Value Blocks (MVB) OK
To reset the switch positions, save a new value of 1.
Special Notes
- If Adaptation will not set with only the 02000 fault present, check TSB 61-08-05 (2010940, NAR only)
- If fault code 00003 - Control Module: Defective -or- Control Module: No or Incorrect Basic Setting / Adaptation will not clear after replacing the 26 module try locking the vehicle doors so the CAN Bus modules go into sleep mode. Upon waking back up, the internal CAN Bus modules on the Comfort Bus may begin to communicate properly.
Measuring Block Data
Reading Roof Electronics Switch Conditions, Electric Power Top Closed
Measuring Block Group 001 (Roof Closed) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Field 2 | X | Field 3 | Data | |||||||||||||
1 | 1 | 0 | 1 | 1 | 0 | 1 | 0 | 1 | 0 | X | 1 | 0 | 1 | 0 | F201 | |
F290 | ||||||||||||||||
F293 | ||||||||||||||||
F200 | ||||||||||||||||
X | ||||||||||||||||
Not used, always "0" | ||||||||||||||||
F292 | ||||||||||||||||
X | ||||||||||||||||
F171 | ||||||||||||||||
F202 | ||||||||||||||||
F294 | ||||||||||||||||
F295 | ||||||||||||||||
F172 | ||||||||||||||||
Switch Point for Bow UP | ||||||||||||||||
Switch Point for Bow OPEN | ||||||||||||||||
Switch Point for Bow DEAD CENTER |
Reading Roof Electronics Switch Conditions, Electric Power Top Opened
Measuring Block Group 001 (Roof Opened) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Field 2 | X | Field 3 | Data | |||||||||||||
0 | 0 | 1 | 0 | 1 | 0 | 0 | 1 | 1 | 0 | X | 1 | 0 | 1 | 0 | F201 | |
F290 | ||||||||||||||||
F293 | ||||||||||||||||
F200 | ||||||||||||||||
X | ||||||||||||||||
Not used, always "0" | ||||||||||||||||
F292 | ||||||||||||||||
X | ||||||||||||||||
F171 | ||||||||||||||||
F202 | ||||||||||||||||
F294 | ||||||||||||||||
F295 | ||||||||||||||||
F172 | ||||||||||||||||
Switch Point for Bow UP | ||||||||||||||||
Switch Point for Bow OPEN | ||||||||||||||||
Switch Point for Bow DEAD CENTER |
Video Link
http://www.youtube.com/watch?v=Q_SumTD87lQ
- Note that this video will be replaced with a more detailed A4 Cabriolet Top Operation video.