Difference between revisions of "01406"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) |
RtWiKiSyS0p (talk | contribs) m |
||
(One intermediate revision by the same user not shown) | |||
Line 16: | Line 16: | ||
* Check Fuel Supply for Leaks | * Check Fuel Supply for Leaks | ||
* Perform Function Test until all Air is out of the Fuel Supply System | * Perform Function Test until all Air is out of the Fuel Supply System | ||
+ | ** Perform Basic Setting ''(see Special Notes for further Instructions)'' | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
* This fault may occur due to the auxiliary heating start up, while all related components and functions are free of faults. | * This fault may occur due to the auxiliary heating start up, while all related components and functions are free of faults. | ||
+ | |||
+ | |||
+ | * When found in [[VW Touran (1T) Auxiliary Heating|VW Touran (1T): Auxiliary Heating]] ''(or similar)'', perform [[VW Touran (1T) Auxiliary Heating#Basic Setting|Basic Setting]]. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 13:28, 21 September 2007
01406 - No Flame
Possible Symptoms
- Smoke
Possible Causes
- Air in Fuel Supply
- Possibly due to "dynamic driving style" while tank on reserve.
- Fuel Supply leaking
Possible Solutions
- Check Fuel Supply for Leaks
- Perform Function Test until all Air is out of the Fuel Supply System
- Perform Basic Setting (see Special Notes for further Instructions)
Special Notes
- This fault may occur due to the auxiliary heating start up, while all related components and functions are free of faults.
- When found in VW Touran (1T): Auxiliary Heating (or similar), perform Basic Setting.