01406 - No Flame
Possible Symptoms
- Smoke
Possible Causes
- Air in Fuel Supply
- Possibly due to "dynamic driving style" while tank on reserve.
- Fuel Supply leaking
Possible Solutions
- Check Fuel Supply for Leaks
- Perform Function Test until all Air is out of the Fuel Supply System
- Perform Basic Setting (see Special Notes for further Instructions)
Special Notes
- This fault may occur due to the auxiliary heating start up, while all related components and functions are free of faults.
- When found in VW Touran (1T): Auxiliary Heating (or similar), perform Basic Setting.