+ | __FORCETOC__ | ||
+ | |||
+ | '''Address 14: Susp. Elect. (J250)''' Labels: 3C0-907-376.clb | ||
+ | Part No SW: 3C0 907 376 A HW: 3C0 907 376 | ||
+ | Component: DAEMPFUNGS-SG H07 0070 | ||
+ | |||
+ | |||
+ | == Basic Setting == | ||
=== Electronic Damping Control J250 - Basic Settings === | === Electronic Damping Control J250 - Basic Settings === | ||
Line 35: | Line 43: | ||
'''[Go!]'''<br> | '''[Go!]'''<br> | ||
The values displayed should be the learned values as displayed in the Basic Settings window.'''<br> | The values displayed should be the learned values as displayed in the Basic Settings window.'''<br> | ||
+ | <font color=white>E?ID=151928</font> |
Latest revision as of 09:35, 20 September 2019
Address 14: Susp. Elect. (J250) Labels: 3C0-907-376.clb Part No SW: 3C0 907 376 A HW: 3C0 907 376 Component: DAEMPFUNGS-SG H07 0070
Basic Setting
Electronic Damping Control J250 - Basic Settings
Prerequisites:
- Battery Voltage = 12.0 - 14.0 V
- No fault codes other than 01087 - Basic Setting Not Performed
- Vehicle is lifted off the ground, on a suitable vehicle lift
[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.
- Group-054 Field-1 = G78 - Min value
- Group-054 Field-2 = G78 - Max value
- Group-055 Field-1 = G289 - Min value
- Group-055 Field-2 = G289 - Max value
Look at:
Group-003 - Field-1,2,3 - Actual Sensor values
- If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then Basic settings can be performed, if not inspect suspension or sensors.
[Security Access - 16]
Enter 31564, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]
The New values should be displayed.
- To check the learned values, check Measuring Value Group-008.
[Meas. Blocks - 08]
Group 008
[Go!]
The values displayed should be the learned values as displayed in the Basic Settings window.