== | == 18502/P2070/008304 - Intake Manifold Tuning Valve (Bank 1): Stuck Open == | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== |
Revision as of 17:20, 30 April 2011
18502/P2070/008304 - Intake Manifold Tuning Valve (Bank 1): Stuck Open
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Reduction of power at higher RPMs
Possible Causes
- Vacuum leak
- Faulty Intake Manifold Tuning (IMT) Valve Position Sensor (G513)
- Intake Manifold Runner binding or sticking
Possible Solutions
- Replace failed vacuum line
- Check Intake Manifold Tuning (IMT) Valve Position Sensor (G513) and wiring, see repair manual.
Special Notes
- When found in 2005 - 2008 Audi A4 and A6 with 3.2L FSI engines, please see TSB 2019485/1