Difference between revisions of "VW Scirocco (13) Suspension Electronics"

From Ross-Tech Wiki
 
Line 1: Line 1:
 
__FORCETOC__
 
__FORCETOC__
 +
 +
'''Address 14: Susp. Elect. (J250)'''      Labels: 3C0-907-376.clb
 +
    Part No SW: 3C0 907 376 A    HW: 3C0 907 376
 +
    Component: DAEMPFUNGS-SG H07 0070
 +
  
 
== Basic Setting ==
 
== Basic Setting ==

Latest revision as of 09:35, 20 September 2019


Address 14: Susp. Elect. (J250)       Labels: 3C0-907-376.clb
   Part No SW: 3C0 907 376 A    HW: 3C0 907 376
   Component: DAEMPFUNGS-SG H07 0070


Basic Setting

Electronic Damping Control J250 - Basic Settings

Prerequisites:


[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.

  • Group-054 Field-1 = G78 - Min value
  • Group-054 Field-2 = G78 - Max value


  • Group-055 Field-1 = G289 - Min value
  • Group-055 Field-2 = G289 - Max value


Look at:
Group-003 - Field-1,2,3 - Actual Sensor values

  • If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then Basic settings can be performed, if not inspect suspension or sensors.


[Security Access - 16]
Enter 31564, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]

The New values should be displayed.

  • To check the learned values, check Measuring Value Group-008.

[Meas. Blocks - 08]
Group 008
[Go!]
The values displayed should be the learned values as displayed in the Basic Settings window.
E?ID=151928