Audi A6 (4B) Level Control (4-Wheel)
Coding
- 25500 = Standard
Security Access
Adaptation
Basic Setting
Special Procedures
Suspension Level Control Calibration
- See How-To: Suspension Level Control Calibration
Before starting the procedure, measure and write down the height of each corner of the vehicle. Measure between the center of the wheel (the space in between the center two rings of the Audi logo) and the lower edge of the fender. All measurements have to be done in Millimeters (mm). A diagram is shown here: [1]
Prerequisites:
- Transmission in park/neutral.
- Start the vehicle, keep the engine running and do not switch off the ignition.
- Doors have to stay closed, otherwise the system is not ready.
[Select]
[34 - Level Control]
[Login - 11]
Enter 31564
[Do It!]
[Adaptation - 10]
Use the [Up] button to scroll up to channel 01. The suspension should automatically adjust its ride height to level 2 for calibration. After the suspension has finished adjusting, each of the four boxes at the top of the Adaptation screen should show "N/A".
Channel 01: Left Front
In the New Value field, enter the measurement from the LEFT FRONT corner in millimeters.
[Test] Make sure that Test Value shows the number you just entered and click [Save]
On the confirmation sure that you are saving the value in millimeters for the LEFT FRONT corner to channel 01 and click [Yes]
Use the [Up] button to scroll up to channel 02. In the New Value field, enter the measurement from the RIGHT FRONT corner in millimeters and click [Test] Make sure that Test Value shows the number you just entered and click [Save]
[Test]
[Save]
VCDS will pop up a confirmation screen. Make sure that you are saving the value in millimeters for the RIGHT FRONT corner to channel 02.
[Yes]
Use the [Up] button to scroll up to channel 03. In the New Value field, enter the measurement from the LEFT REAR corner in millimeters.
[Test]
[Save]
VCDS will pop up a confirmation screen. Make sure that you are saving the value in millimeters for the LEFT REAR corner to channel 03.
[Yes]
Use the [Up] button to scroll up to channel 04. In the New Value field, enter the measurement from the RIGHT REAR corner in millimeters.
[Test]
[Save]
VCDS will pop up a confirmation screen. Make sure that you are saving the value in millimeters for the RIGHT REAR corner to channel 04.
[Yes]