00266
From Ross-Tech Wiki
00266 - Solenoid Valve 5 (N92)
00266 - Solenoid Valve 5 (N92): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
- Solenoid Valve 5 (N92) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
- Check/Replace Solenoid Valve 5 (N92)
- See Measuring Value Blocks (MVB)
- Perform Output Test
Special Notes
- In some vehicles, (N92) may be refereed to as (N216) in the factory repair manual.
- When found in the following 6-Speed Automatic Transmission (09G) equipped NAR (North American Market) vehicles, perhaps in conjunction with P0798, a flash update may be required:
- 2012 2.5L VW Jetta Sedan, JSW (Jetta Sportwagon), Golf, Beetle and Passat
- 2012 VW CC 3.6L
- 2012 VW Tiguan 2.0T
- See TSB 01-12-34 -or- TPI 2029268 for details.